Menu
Your Cart

3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V

3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
3HP 0.75kw/1.5kw/2.2kw Variable Frequency Drive Inverter VFD 3 Phase To 3 Phase VFD 380V
$129.99
Ex Tax: $129.99
  • Stock: In Stock
  • Model: MZ004131
  • SKU: MZ004131

Available Options

Features:

-Quick heat dissipation and longer service life.
-0.1s~3600min can be set continuously, S-type and linear mode are optional.
-LK710 series inverter is a high-performance vector heavy-duty inverter.
-Strong anti-interference ability, large low-frequency torque, high precision.
-Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal motor parameter tuning, internal memory failure, etc.
-According to the needs, you can choose dynamic voltage regulation, static voltage regulation, and unregulated regulation to obtain the most stable operation effect.
-Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc.

Specifications:

Name: Variable Frequency Inverter
Color: black
Input: 3PH AC 380V 50-60Hz
Output: 3PH 0-500Hz
Power: 0.75KW/1.5KW/2.2KW
Current: 2.1A/3.8A/5.1A
Control Method: voltage vector
Size: 151 x 100 x 133mm/6 x 4 x 5in

Safety Precaution:

1. Before wring, please make sure that the input power is off.
2. The  wring  work  should  be  operated  by  the  professional electrical engineer.
3. The grounding terminals must be connected with the ground.
4. Having  paused  circuit  wiring  emergently,  please  make  sure  that  the check is effective.
5. Do  not  connect  the  output  wire  of  the  inverter  with  the  shell,  and  pay attention that the output wire should not be short-circuited.
6. Please  check  whether  the  voltage  of  the  AC  main  circuit  power  is consistent with the rated voltage of the inverter.
7. Do not do the voltage withstand test on the inverter.
8. Please connect the brake resistor according to the wiring diagram.
9. Do not connect the power to the V, U, W output terminals.
10. Do not connect the contactor with the output circuit.
11.  Mare  sure  to  install a protection  cover  before  power-on.  When removing the cover, be sure to make the power off.
12. If you want to reset the inverter with the retry function, do not get close to the mechanical equipment,  because  the  inverter  will  restart  suddenly when the alarm stops.
13. Confirm that  the  operation signal  is cut off.  Before reset the alarm device,or the inverter may start suddenly.
14. Do  not  touch  the  terminals of  inverter,  which  are  very  dangerous because there is high voltage on them.
15. When power is on, do not change the wiring and terminal.
16. Cut  off  the  main  circuit  power before doing some  check  and maintain work.
17. Do not arbitrarily reform the inverter.

Package Included:

1 x Variable Frequency Inverter

Details Pictures:

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-1

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-2

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-3

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-4

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-5

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-6

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-7

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-8

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-9

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-10

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-11

3HP-075kw15kw22kw-Variable-Frequency-Drive-Inverter-VFD-3-Phase-To-3-Phase-VFD-380V-1761480-12


Write a review

Note: HTML is not translated!
Bad Good
Captcha