DSO4254B 250MHz Digital Storage Oscilloscope 4 Channels 1GS/s Sample Rate Portable Oscilloscope EU Plug
DSO4254B 250MHz Digital Storage Oscilloscope 4 Channels 1GS/s Sample Rate Portable Oscilloscope EU Plug
$589.99
Ex Tax: $589.99
- Stock: In Stock
- Model: MZ004369
- SKU: MZ004369
Features:
4CH oscilloscope+EXT+DVM+auto range function
250MHz bandwidth,minimum range 500μV /div,1GS/s sample rate.
Over 32 types of auto measurement function
Advanced digital trigger system, high trigger sensitivity.
Over 14 types of trigger function: edge, overtime, pulse, pattern, interval, etc.
Serial bus triggering and decode, Bus protocol information can be quickly and intuitively displayed in table form.
Integrated USB Host/Device, convenient to communicate with PC. Support U-stick storage/systerm update.
Support a variety of SCPI remote control command
Stable and reliable quality, sturdy and durable.
Specifications:
Model | DSO4254B | DSO4204B | DSO4104B | DSO4084B |
Bandwidth | 250MHz | 200MHz | 100MHz | 80MHz |
Horizontal | ||||
Sample Rate Range | 1GS/s | |||
Waveform Interpolation | (sin x)/x | |||
Record Length | Maximum 64K samples per single channel; | |||
Maximum 32K samples per dual-channel (4K, 32K optional) | ||||
SEC/DIV Range | 2ns/div~100s/div | |||
1, 2, 5 sequences | ||||
Sample Rate and Delay Time Accuracy | ±50ppm | |||
ΔTime Measurement Accuracy (Full Bandwidth) | Single-shot, Normal mode ± (1 sample interval +100ppm × reading + 0.6ns) | |||
>16 averages ± (1 sample interval + 100ppm × reading + 0.4ns) | ||||
Sample interval = s/div ÷ 200 | ||||
Vertical | ||||
AD Converter | 8-bit resolution, each channel sampled simultaneously | |||
VOLTS/DIV Range | 500μV/div to 10V/div at input BNC | |||
Position Range | 500μV/div~20mV/div, ±400mV | |||
50mV/div~200mV/div, ±2V | ||||
500mV/div~2V/div, ±40V | ||||
5V/div~10V/div, ±50V | ||||
Selectable Analog Bandwidth Limit, typical | 20MHz | |||
Low-Frequency Response (-3db) | ≤10Hz at BNC | |||
Rise Time at BNC, typical | DSO4254B | DSO4204B | DSO4104B | DSO4084B |
<1.4ns | ≤1.8ns | <3.5ns | ≤4.4ns | |
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div | |||
±4% for Normal or Average acquisition mode, 5mV/div to 500μV/div | ||||
Note: Bandwidth reduced to 6MHz when using a 1X probe. | ||||
Acquisition | ||||
Acquisition Modes | Normal, Peak Detect, Average, and HR | |||
Acquisition Rate, typical | Up to 2000 waveforms per second per channel (Normal acquisition mode, no measurement) | |||
Single Sequences | Acquisition Mode | Acquisition Stop Time | ||
Normal, Peak Detect | Upon single acquisition on all channels simultaneously | |||
Average | After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128 | |||
Trigger | ||||
Mode | Auto, Normal | |||
Level | CH1~CH4 | ±4 divisions from the center of the screen | ||
EXT | 0~3.3V | |||
Holdoff Range | 20ns ~ 10s | |||
Trigger Level Accuracy | CH1~CH4 | 0.2div × volts/div within ±4 divisions from center of screen | ||
EXT | ± (6% of setting + 40mV) | |||
Edge Trigger | ||||
Slope | Rising, Falling, Rising&Falling | |||
Source | CH1~CH4/EXT | |||
Pulse Width | ||||
Polarity | Positive, Negative | |||
Condition(When) | <, >, ≠, = | |||
Source | CH1~CH4 | |||
Width Range | 8ns ~ 10s | |||
Resolution | 8ns | |||
Video Trigger | ||||
Signal Standard | NTSC, PAL | |||
Source | CH1~CH4 | |||
Sync | ScanLine, LinrNum, OddField, EvenField, and AllField | |||
Slope Trigger | ||||
Slope | Rising, Falling | |||
Condition(When) | <, >, ≠, = | |||
Source | CH1 ~ CH4 | |||
Time Range | 8ns ~ 10s | |||
Resolution | 8ns | |||
Overtime Trigger | ||||
Source | CH1~CH4 | |||